Sartorius QUINTIX125D-1S Manual, Explained: Setup, isoCAL and Calibration
The Sartorius QUINTIX125D-1S manual, made simple: set up the Quintix dual-range 60 g / 120 g × 0.01 mg / 0.1 mg semi-micro balance, level it, and run isoCAL. The QUINTIX125D-1S is in stock at MNM Scales for $5,199.00 (regular $7,570.00).
Short answer: the official Sartorius QUINTIX125D-1S manual is the Secura, Quintix and Practum Laboratory Balances Operating Instructions, publication 98648-019-43 (WSE6004-e220609, last updated June 2022). It covers installation, leveling, isoCAL, external calibration, the touchscreen applications, and the specification tables. Model-specific figures on this page come from the official Sartorius Quintix datasheet, QUINTIX125D-1x column, for US standard 1S models. If the carton arrived cold, condition the balance for about two hours at the bench with the AC adapter disconnected (official section 4.3). Then connect the included YEPS01-15V0W power supply, allow at least 30 minutes of warm-up after the first connection to power (section 4.6), center the bubble in the level indicator (section 5.2.2), and run isoCAL. Here is an NTEP alternative: the Sartorius BCE124-1NUS, 120 g × 0.1 mg, NTEP Class I, Certificate of Conformance 22-017A1 (Active). The 30 g × 0.01 mg Quintix sibling is the QUINTIX35-1S. MNM Scales is an authorized Sartorius dealer and stocks the QUINTIX125D-1S at $5,199.00 (regular $7,570.00). For how 0.01 mg readability compares with analytical and microbalances, see microbalance vs semi-micro vs analytical balance. For line pricing across Sartorius families, see our Sartorius balance price guide.
We sell, calibrate and repair Sartorius Quintix balances from our Cypress, TX shop, and we ship from our Houston-area warehouse at 21249 FM 529 Rd, Cypress, TX 77433.
Sartorius QUINTIX125D-1S manual at a glance: specifications
Figures below are from the official Sartorius Quintix datasheet, “Models with internal adjustment feature, without approval,” QUINTIX125D-1x column (x = S for US standard 1S models), read on November 18, 2026. Setup and isoCAL steps are from the official Operating Instructions 98648-019-43 (WSE6004-e220609, June 2022).
| Item | QUINTIX125D-1S |
|---|---|
| Capacity × readability (dual range) | 60 g × 0.01 mg / 120 g × 0.1 mg |
| Repeatability, typical, at 5% load | ±0.02 mg / ±0.07 mg |
| Repeatability, typical, at approximately maximum load | ±0.03 mg / ±0.07 mg |
| Linearity deviation, limits / typical | ±0.1 mg / ±0.1 mg limits; typical ±0.06 mg |
| Sensitivity drift between +10 °C and +30 °C | ±1 ppm/K |
| Typical stabilization time | ≤4.0 s / ≤1.5 s |
| Typical measurement time | ≤6.0 s / ≤2.0 s |
| Weighing pan | Ø 80 mm |
| Weighing chamber height | 218 mm (pan upper edge to lower edge of the upper draft-shield panel) |
| Net weight, approx. | 8.80 kg |
| IP protection class | IP43 |
| Adjustment | isoCAL and internal adjustment |
| isoCAL triggers | 1.5 K temperature change, or a 4-hour interval |
| Recommended external test weight | 100 g, OIML class E2 |
| Warm-up time after first connection to power | At least 30 minutes (official section 4.6) |
| Acclimatization if the device arrives cold | About 2 hours, disconnected from power (section 4.3) |
| USP chapter 41 optimum / typical minimum initial weighing | 0.0082 g / 0.04 g |
| Ambient temperature for the stated specifications | +10 °C to +30 °C, indoor use |
| Power | Sartorius YEPS01-15V0W, 100–240 V~, 50–60 Hz (included) |
Live prices at MNM Scales
Prices and stock are from our live store on November 18, 2026.
| Model | Capacity × d | Calibration | Price | Stock |
|---|---|---|---|---|
| Sartorius QUINTIX125D-1S (#995) | 60 g × 0.01 mg / 120 g × 0.1 mg | isoCAL / internal | $5,199.00 (regular $7,570.00) | In stock |
| Sartorius QUINTIX35-1S (#97) | 30 g × 0.01 mg | isoCAL / internal | $5,199.00 (regular $6,980.00) | In stock |
| Sartorius QUINTIX64-1S (#7772) | 60 g × 0.1 mg | isoCAL / internal | $2,771.00 | In stock |
| Sartorius BCE124-1NUS (#1751) | 120 g × 0.1 mg, NTEP Class I | NTEP alternative, CC 22-017A1 | $1,899.00 (regular $2,710.00) | In stock |
Setup from the Sartorius QUINTIX125D-1S manual
Choose a stable, even surface that stays free of vibration, heat, drafts, heavy traffic, moisture and strong electromagnetic fields (official section 4.3). Lift the balance by the base so the draft shield stays unloaded (section 4.4). For Quintix models with a draft shield, fit the in-use dust cover and draft shield, then the shield plate, shield disk, pan support and weighing pan; the pan draft shield is specified for models with 0.1 mg readability (section 4.2). The QUINTIX125D-1S uses an 80 mm pan and a 218 mm weighing chamber.
If the carton arrived cold, condition the balance for about two hours with the AC adapter disconnected so condensation can clear (section 4.3). Attach the country-specific plug adapter to the official YEPS01-15V0W AC adapter, connect power, and allow at least 30 minutes of warm-up after that first connection (sections 4.5 and 4.6). Switch the balance on from the display; the first-time startup wizard walks through language, date and time (section 4.7). Quintix models use a conventional glass level indicator to the left of the display: twist the two front leveling feet until the air bubble sits in the center of the circular marking (section 5.2.2), then run isoCAL or an internal adjustment.
How to use isoCAL and calibrate the QUINTIX125D-1S
isoCAL is the automatic internal adjustment on Quintix models, including the QUINTIX125D-1S. The official datasheet lists the triggers as a 1.5 K temperature change or a 4-hour interval. In the setup menu you can set isoCAL to Off, Info with a manual start, or Automatic (official section 6 / isoCAL options). When the function is set to Automatic, calibration and adjustment start on those triggers. When it is set to Info, manual start, select the isoCAL button on the display to begin (official section 8.3). The display then shows a report of the internal calibration and adjustment, including the deviations.
For an external check or adjustment, official section 8 calls for a 100 g OIML E2 test weight on this model (datasheet recommended weight). Make sure the weighing pan is empty, zero the balance, open the menu, select CAL, then choose CAL-Extern and follow the on-screen prompts (section 8). Keep the bench free of vibration and drafts while the balance is measuring.
QUINTIX125D-1S vs QUINTIX35-1S
The QUINTIX125D-1S is a dual-range semi-micro balance: 60 g × 0.01 mg and 120 g × 0.1 mg, in stock at $5,199.00 (regular $7,570.00). The QUINTIX35-1S stays at 0.01 mg across a 30 g capacity, in stock at $5,199.00 (regular $6,980.00). Both use isoCAL with the same 1.5 K / 4-hour triggers, an 80 mm pan and a 218 mm chamber. Choose the 125D when you need the extra 120 g coarse range; choose the 35-1S when every weighing stays at 0.01 mg on a 30 g maximum. The QUINTIX64-1S is a 60 g × 0.1 mg analytical Quintix at $2,771.00 if 0.1 mg readability is enough.
Notes from our Cypress, TX shop
MNM Scales is an authorized Sartorius dealer. We keep the QUINTIX125D-1S in stock in Cypress and can add in-house or NIST-traceable calibration before the balance ships. Our technicians also handle mail-in work from anywhere in the US and on-site service in the Houston area. If you are comparing Quintix, Entris II and other Sartorius lines, start with our Sartorius balance price guide and the microbalance vs semi-micro vs analytical guide.
NTEP and the BCE124-1NUS
The QUINTIX125D-1S is a non-NTEP model for in-house use. Here is an NTEP alternative: the Sartorius BCE124-1NUS, 120 g × 0.1 mg, NTEP Class I, Certificate of Conformance 22-017A1 (Active, Sartorius Corp, BCE Series, issued March 28, 2025). On that certificate the BCE124-1NUS is 120 g, e = 0.001 g, d = 0.0001 g, nmax 120,000, Class I, 17 °C to 27 °C, with a 240 mm draft shield and a 90 mm pan. That alternative matches the 125D’s 120 g coarse range and 0.1 mg readability; the 125D’s fine range of 60 g × 0.01 mg is a tighter laboratory readability than the NTEP Entris II model. For definitions, use what NTEP and legal for trade mean.
Calibration, repair and rentals
Request calibration through Get a Quote or call (832) 290-3120, or start from our Houston scale calibration page. Calibration is priced by readability as well as capacity. The QUINTIX125D-1S reads to 0.01 mg, so semi-micro calibration applies: in-house calibration with a certificate is $295.00, and NIST-traceable calibration with a certificate is $1,095.00. Mail-in calibration is nationwide. Calibration usually takes 1–3 business days after we receive the balance. On-site service is a $295.00 service call plus $2 per mile round trip, with calibration priced per scale on top. We repair all brands and types of scales, including Sartorius Quintix balances. For scale rentals, call (832) 290-3120 or request a quote.
Frequently asked questions
Where can I get the Sartorius QUINTIX125D-1S manual?
The official Sartorius QUINTIX125D-1S manual is the Secura, Quintix and Practum Laboratory Balances Operating Instructions, publication 98648-019-43 (WSE6004-e220609, last updated June 2022). This page walks through setup, leveling, isoCAL, external calibration, and the official specification table for the Sartorius QUINTIX125D-1S we stock at $5,199.00 (regular $7,570.00). Model-specific numbers are taken from the official Sartorius Quintix datasheet.
How do I set up the Sartorius QUINTIX125D-1S?
Place it on a stable, even, draft-free bench and lift it by the base. Fit the draft shield, shield plate, shield disk, pan support and 80 mm weighing pan (official section 4.2). If the carton arrived cold, condition the balance for about two hours with the AC adapter disconnected (section 4.3). Connect the included YEPS01-15V0W power supply, allow at least 30 minutes of warm-up after the first connection to power (section 4.6), center the bubble with the two front leveling feet (section 5.2.2), and run isoCAL or an internal adjustment.
How does isoCAL work on the QUINTIX125D-1S?
isoCAL is the automatic internal adjustment on Quintix models, including the QUINTIX125D-1S. The official datasheet lists the triggers as a 1.5 K temperature change or a 4-hour interval. In the menu, isoCAL can be set to Off, Info with a manual start, or Automatic. When Automatic is selected, calibration and adjustment start on those triggers. When Info, manual start is selected, press the isoCAL button on the display to begin. The display then shows a report of the deviations and the adjustment result (official section 8.3).
Is the Sartorius QUINTIX125D-1S NTEP?
The QUINTIX125D-1S is a non-NTEP model for in-house use. Here is an NTEP alternative: the Sartorius BCE124-1NUS, 120 g × 0.1 mg, NTEP Class I, Certificate of Conformance 22-017A1 (Active), in stock at $1,899.00. That model covers the 125D’s 120 g × 0.1 mg coarse range. For definitions, see what NTEP and legal for trade mean.
How does the QUINTIX125D-1S compare with the QUINTIX35-1S?
The QUINTIX125D-1S is dual range, 60 g × 0.01 mg and 120 g × 0.1 mg, at $5,199.00 (regular $7,570.00). The QUINTIX35-1S is 30 g × 0.01 mg at $5,199.00 (regular $6,980.00). Both use isoCAL and an 80 mm pan. Choose the 125D for the extra 120 g range; choose the 35-1S when the work stays at 0.01 mg up to 30 g.
Can I add calibration to a QUINTIX125D-1S before it ships?
Yes. The QUINTIX125D-1S reads to 0.01 mg, so semi-micro calibration applies: in-house calibration with a certificate is $295.00, and NIST-traceable calibration with a certificate is $1,095.00. Request it through Get a Quote or call (832) 290-3120. Mail-in calibration is nationwide, and turnaround is usually 1–3 business days after we receive the balance.