A&D EK-1200i Manual, Explained: Setup, Units, Counting, RS-232 and Power

Short answer: the A&D EK-1200i manual (the shared EK-i/EW-i instruction manual) comes down to five jobs: set the balance on a firm, draft-free bench and level it; warm it up for at least 30 minutes; choose your units with MODE and store the ones you use; set counting, percent and comparator from the SAMPLE key and function menu; and match the RS-232C settings to your printer or PC. Calibration steps and CAL messages are in our separate EK-1200i calibration guide.

View the EK-1200i: price and stock Compare the EK-i series Call (832) 290-3120 Get a quote

A&D publishes one instruction manual for the whole EK-i and EW-i family, so the EK-1200i details are spread across a long document. This guide pulls out what an EK-1200i owner actually uses, in plain language, with the menu names exactly as they appear on the display. You can download the official manual from A&D’s EK-1200i page. MNM Scales has sold, calibrated and repaired scales for over 30 years, and the tips here come from the settings problems we see when balances come in for service.

Unpacking: what should be in the box

  • The EK-1200i balance, stainless steel weighing pan and pan support.
  • The AC adapter and the instruction manual.
  • Not included unless ordered: the EKW-09i battery pack (not included), printer, RS-232C cable, calibration weight and comparator relay option.
  • Check the label on the right side for the model and serial number, and inspect the adapter cord for nicks before plugging it in.
  • Keep the box and foam for mail-in service.

Installation and warm-up

  1. Choose a firm, level bench away from drafts, heaters, air conditioning vents, direct sun, vibration and magnetic fields.
  2. Let a balance that rode in a cold or hot truck reach room temperature before powering it on.
  3. Fit the pan support and pan, then turn the leveling feet until the bubble in the spirit level is centered.
  4. Plug in the AC adapter and press ON/OFF. The display shows all segments, then 0.0 g with the ZERO mark. Power-on zero works within ±10% of capacity; with more than that on the pan, the balance tares it instead.
  5. Leave it on for at least 30 minutes before weighing. A&D calls for calibration when the balance is first installed or moved; follow our EK-1200i calibration guide for that step.

The four keys

KeyPressHold
ON/OFFPower on or off—
MODEStep through stored units, counting and percent; exit menus—
SAMPLEEnter unit-weight storing (counting) or 100% storing (percent)Open the function menu (func)
PRINTSend data out the RS-232C port; store a value in menus—
RE-ZEROZero the display, or tare a container—
Key functions from A&D’s EK-i/EW-i instruction manual.

Weighing units on the EK-1200i

Press MODE to step through the units stored in the balance. The EK-1200i is NTEP approved in grams, ounces, troy ounces, pounds, pennyweight, carats and grains.

UnitDisplayEK-1200i capacity x readability
Gramg1200 x 0.1 g
Ounce (avoir)oz42.330 x 0.005 oz
Poundlb2.6455 x 0.0005 lb
Troy ounceozt38.580 x 0.005 ozt
Pennyweightdwt771.6 x 0.1 dwt
Metric caratct6000.0 x 0.5 ct
GrainGN18518 x 2 GN
From A&D’s EK-1200i specifications.

Store only the units you use. In the function menu, the Unit item lets you keep, for example, just grams and troy ounces, and choose which unit appears at power-on. That keeps staff from scrolling into the wrong unit. Need to convert paperwork? Use our grain to gram converter.

Counting mode

  1. Press MODE until pcs shows.
  2. Press SAMPLE to enter unit-weight storing. Press SAMPLE again to choose 5, 10, 25, 50 or 100 pieces.
  3. Place a container, if used, and press RE-ZERO so the display shows zero beside the sample size.
  4. Count out that many pieces onto the pan and press PRINT to store the unit weight, then remove them.
  5. Place the parts to be counted; the display shows the piece count.
  • On the EK-1200i the smallest unit weight is 0.1 g and the maximum count is 12,000 pieces.
  • Bigger samples give better counts. If the parts are light, the balance may ask for more pieces (for example, showing 25 -); add that many and press PRINT.
  • aCai (ACAI, automatic counting accuracy improvement) refines the unit weight when you add a few more pieces after storing it and wait for the ACAI mark to turn off; Umin sets the minimum unit weight rule; smpl sets which sample size shows first.
  • Counting is for inventory and production. NTEP labels the counting feature as not for trade, so price by weight. See our counting scale buying guide for high-volume counting.

Percent mode and the HI/OK/LO comparator

  • Percent: press MODE to %, press SAMPLE, press RE-ZERO to zero, place the reference (at least 10 g on the EK-1200i) and press PRINT to store it as 100%. Later loads read as a percentage, to 0.1%.
  • Comparator: set Cp to choose when results are compared (all data, stable data, or only above +4d), enter the upper and lower limits under CpHi and Cplo, and pick the buzzer pattern with bep. HI, OK and LO show on the display.
  • The comparator relay option (not included) switches external lamps or alarms from those results. It shares the option slot with the battery pack, so you can fit one or the other.

Function menu settings

Hold SAMPLE until func appears. Press SAMPLE to move to the next item, RE-ZERO to change the value, PRINT to store it and MODE to return to weighing. Write your settings on a card under the balance so anyone can restore them.

ItemWhat it controlsTypical change
poffAuto power-off after about 5 minutes at zeroOn for battery use
Cond (0 to 4)Response: 0 fast and sensitive, 4 slow and stableRaise if drafts or vibration make the reading wander
st-b (0 to 2)Stability band for the stable markWider band for a busy bench
trcZero tracking on or offUsually on; off for slow evaporation or drip work
pntDecimal point or commaMatch your software
Cp, CpHi, Cplo, bepComparator mode, limits and buzzerCheck weighing and kit verification
prt, pUseOutput mode and print pausePrinter or PC hookups
info, idGLP report format and the balance IDLabs that keep calibration records
bps, btprBaud rate and data bits/parityMatch the printer or software
aCai, Umin, smplCounting accuracy, minimum unit weight, first sample sizeParts counting
ltUpBacklight off, timed (5 to 60 s) or always onSave battery or keep the display lit
UnitUnits stored and the power-on unitLock to the units you use
From the function list in A&D’s EK-i/EW-i instruction manual. Some items may be locked on legally certified units.

RS-232C: printer and computer connection

  • The port is a D-sub 9 pin connector: pin 2 TxD, pin 3 RxD, pin 5 signal ground. Use a straight-through cable to a PC (cable not included).
  • Set bps (1200, 2400, 4800 or 9600) and btpr (7 bits even or odd parity, or 8 bits no parity) to match the other device.
  • Choose how data leaves with prt: on command, with the PRINT key, automatically when a stable load is placed, or as a continuous stream.
  • For an A&D AD-8121 printer (not included), set pUse to 1 for the 1.6-second pause it needs.
  • Each stable reading is sent as a header plus value, for example ST,+00012.34 g. QT marks a count, US an unstable reading and OL an overload.
  • A&D’s free WinCT software logs readings into a spreadsheet on a Windows PC. For USB-only computers, see connecting a scale to a computer by USB or RS-232.

Power: AC adapter, battery and auto power-off

  • The EK-1200i ships with its AC adapter. Use only the adapter supplied for the EK-i; a replacement AC adapter for the EK-600i and EK-1200i is available (not included as a spare).
  • For cordless use, add the EKW-09i rechargeable NiMH battery pack (not included). It installs in the option slot on the back.
  • Charge the pack with the AC adapter connected and the balance turned off. A full charge takes about 15 hours, and a new or long-stored pack may need two or three charges to reach full capacity.
  • Battery life depends on the backlight and how the balance is used, so set ltUp to a short timeout and turn on poff to stretch each charge.
  • When the battery indicator shows the pack is low, switch to the AC adapter or recharge.
  • Cut or pinched adapter cords are among the most common faults we repair. Route the cord behind the bench, and see replacing a scale cable if yours is damaged.

Settings mistakes we see in service

  • Units changed or hidden: someone stored a different unit list, so the balance seems stuck in ounces. Restore it under Unit.
  • Slow or jumpy readings: Cond or st-b was changed. Reset them before assuming a fault.
  • Constant beeping: the comparator buzzer (bep) is on with limits set.
  • Calibration entered by accident: that is a calibration issue, covered step by step in our EK-1200i calibration guide.
  • Load cell wear: repeated overloads and dropped parts take a toll. Keep loads under 1200 g and set items down gently.

Texas note: TDA does not require an NTEP certificate for every device, but the scale must meet NIST Handbook 44 and suit its use; some scales do need one, so we recommend NTEP models and can check yours. See TDA’s scales used in trade guidance (PDF), our TDA scale certification guide and what the RWM-780 placed-in-service form means, or call us or TDA to confirm your use.

Using the EK-1200i at a gold or jewelry counter? Read our legal-for-trade jewelry scale guide. Still choosing a model? See the A&D EK-i series or EK-1200i vs EK-610i, or browse all A&D precision balances.

Ready to order? See current price and stock on the A&D EK-1200i listing. Add-on: the EKW-09i rechargeable battery pack (not included) for cordless use. Want it calibrated before it ships? Add in-house calibration with a certificate ($95) or NIST calibration with a NIST-traceable certificate ($395). Questions? Call (832) 290-3120 or send a quote request.

View price and stock Call (832) 290-3120 Request a quote

Calibration, repair and rentals

Frequently asked questions

Where can I get the A&D EK-1200i manual?

A&D publishes one instruction manual for the EK-i and EW-i series, available from the EK-1200i page on A&D’s website. This guide summarizes the setup, units, counting, RS-232C and power sections for EK-1200i owners.

How do I change units on the EK-1200i?

Press MODE to step through the stored units. To choose which units are stored and which shows at power-on, hold SAMPLE to open the function menu and use the Unit item.

How do I use counting mode on the EK-1200i?

Press MODE until pcs shows, press SAMPLE, press SAMPLE again to choose 5, 10, 25, 50 or 100 pieces, zero with RE-ZERO, place that many pieces and press PRINT. The smallest unit weight is 0.1 g and the maximum count is 12,000 pieces.

How do I open the function menu on the EK-1200i?

Hold SAMPLE until func appears. Press SAMPLE to move between items, RE-ZERO to change a value, PRINT to store it and MODE to return to weighing.

What cable and settings connect the EK-1200i to a computer?

A straight-through D-sub 9 pin RS-232C cable (not included). Match the baud rate (bps) and data/parity (btpr) settings and choose an output mode with prt, then use A&D’s free WinCT software or your own program.

Does the EK-1200i come with a battery?

No. It ships with an AC adapter. The EKW-09i rechargeable NiMH battery pack is an add-on, not included, and takes about 15 hours to charge fully.

Where are the EK-1200i calibration steps?

Calibration and CAL messages are covered in our separate guide, How to Calibrate the A&D EK-1200i. MNM Scales also calibrates EK-1200i balances in-house, by mail-in or on-site.

About the author: MNM Scales

MNM Scales has sold, calibrated and repaired scales and balances for over 30 years. Our TDA-registered technicians calibrate in-house with certificates, offer mail-in and on-site calibration, place commercial scales in service in Texas, and rent all types of scales. We supply customers across aerospace, oil and gas, food, plastics, chemicals, pharmacies to big pharma, and pawn shops. Shop: 21249 FM 529 Rd, Cypress, TX 77433 (by appointment). Call (832) 290-3120 or contact us.

Last updated October 31, 2026. Sources: A&D EK-i/EW-i instruction manual and A&D’s EK-1200i product page. Service prices from our service listings on October 31, 2026.

Leave a Comment