OHAUS SPX1202 Manual: Setup, Modes, Units and Calibration

This SPX1202 manual page covers setup, modes, units and calibration for the OHAUS SPX1202 Scout SPX, a 1,200 g × 0.01 g portable balance that we have in stock at $741.99.

Short answer: the official SPX1202 manual is OHAUS’s Scout SPX series instruction manual (PDF), part number 30268991 rev F, which covers the SPX123 through the SPX8200 and which we host. To set the balance up, release the red transportation lock, fit the pan, level it with the feet until the bubble is centered, connect the AC adapter or four AA batteries and let it warm up for at least 5 minutes. To calibrate, hold Menu until the menu shows, press Yes at CAL, then Yes at SPAN, and place the 1 kg span mass when the display asks for it. The SPX1202 is a Non-NTEP balance for classrooms, labs, field work and production checks. Here is an NTEP alternative: OHAUS SJX1502N/E, 1,500 g, NTEP Class II with e = 0.1 g (CC 16-015A2, Active), $275.00 (regular $1,507.00), in stock. MNM Scales calibrates balances up to 2.2 kg in-house with a certificate for $95.00, NIST-traceable for $395.00, or on site for $295 plus $2 per mile round trip.

In stock: $741.99 (regular $1,412.00) for the OHAUS SPX1202. Contact us or call (832) 290-3120 with a question about setup, calibration or an order.

Shop the SPX1202   Call (832) 290-3120   Get a Quote

This SPX1202 manual guide walks through OHAUS’s Scout SPX series instruction manual (PDF) for the OHAUS SPX1202, the 1,200 g × 0.01 g Scout with a 170 × 140 mm pan, a backlit LCD and span or linearity calibration. For the 2,200 g sibling with the same 0.01 g readability read our SPX2202 manual guide, for the 0.1 g models see the SPX2201, SPX621 and SPX421 guides, and for choosing a size see scale capacity and readability.

SPX1202 at a glance

Prices are from our live store on November 26, 2026.

ModelCapacity × readabilityNTEPPrice
OHAUS SPX12021,200 g × 0.01 g, external span or linearity calibrationNon-NTEP. Here is an NTEP alternative: OHAUS SJX1502N/E, 1,500 g, NTEP Class II with e = 0.1 g (CC 16-015A2, Active), $275.00 (regular $1,507.00), in stock.$741.99 (regular $1,412.00), in stock
OHAUS SJX1502N/E1,500 g × 0.01 g, certified with e = 0.1 g, external calibrationNTEP Class II, CC 16-015A2$275.00 (regular $1,507.00), in stock
ItemSPX1202
Capacity1,200 g
Readability0.01 g
Repeatability (standard deviation)0.02 g
Linearity0.03 g
Stabilization time1.5 seconds
Span calibration mass1 kg (not included)
Linearity calibration masses500 g and 1 kg
Application modesWeighing, parts counting, percent weighing, check weighing, totalization, display hold
DisplayBacklit LCD, 6-digit 7-segment, 20 mm digits
Weighing pan170 × 140 mm (6.7 × 5.5 in), 304 stainless steel
PowerAC adapter (input 100 to 240 V) or four AA batteries
Operating conditions10 to 40 °C (50 to 104 °F), 10% to 80% relative humidity, non-condensing, indoor use only
Interfaces (optional kits)RS232, USB host, USB device, Ethernet or Bluetooth
Net weight1 kg (2.2 lb)
NTEPNon-NTEP. Here is an NTEP alternative: OHAUS SJX1502N/E, 1,500 g, NTEP Class II with e = 0.1 g (CC 16-015A2, Active), $275.00 (regular $1,507.00), in stock.

Source: the OHAUS Scout SPX instruction manual (PDF) (sections 2 to 6). OHAUS notes that availability of units and application modes varies by model and local regulations.

Setting up the SPX1202

  1. Release the transportation lock: turn the red pointer on the subplatform 90 degrees counter-clockwise.
  2. Fit the pan: the SPX1202 has a 170 × 140 mm pan, which goes straight down onto the subplatform.
  3. Pick a spot: a clean, stable surface away from drafts, rapid temperature changes, magnetic fields and vibration.
  4. Level it: turn the feet at each corner until the bubble in the small round window on the front sits in the circle. Level it again each time you move it.
  5. Power it: plug the AC adapter into the jack on the rear, or install four AA batteries with the polarity shown in the compartment.
  6. Warm up and calibrate: OHAUS recommends warming up for at least 5 minutes after power on, and calibrating when the balance is first installed and whenever it is moved.

Press and hold the On/Zero Off button for 1 second to turn the balance on. It runs a display test, shows the software version and enters weighing. Press and hold the same button until OFF shows to turn it off. A security slot at the rear takes an optional cable and lock.

Buttons, units and basic weighing

ButtonShort pressLong press
Zero/OnTurns the balance on, or sets zero if it is onTurns the balance off
PrintSends the current value to the selected COM port if AUTOPRINT is offChanges the weighing unit
FunctionStarts an application function, such as storing a weight in totalizationChanges the application mode
TareEnters or clears a tare valueEnters the user menu

To weigh, tare an empty container with the Tare button, add the sample and read the display once the stable symbol shows. The SPX1202 supports these units, each switched on in the Unit menu: g, kg, ct, N, oz, ozt, dwt, lb, lb:oz, grn, three tael units, tical, tola and a custom unit (C). The Unit button steps through the ones you turn on.

UnitCapacity x readability on the SPX1202
Kilogram (kg)1.2 x 0.00001
Gram (g)1200 x 0.01
Carat (ct)6000 x 0.05
Newton (N)11.7679 x 0.0001
Ounce (oz)42.3290 x 0.0005
Troy ounce (ozt)38.5810 x 0.0005
Pennyweight (dwt)771.62 x 0.01
Pound (lb)2.64555 x 0.00005
Pound:ounce (lb:oz)2lb:10.3290oz x 0.0005oz
Grain (grn)18518.8 x 0.2

Counting, percent, check weighing and more

Counting parts

  1. Place an empty container and press Tare.
  2. Press and hold Mode until Count shows. If a stored average piece weight (APW) exists, press Yes at the clear-APW prompt to replace it, or No to keep it.
  3. With Put 10 (or another sample size) showing, press No or Back to choose 5, 10, 20, 50 or 100 pieces.
  4. Place that many pieces on the pan and press Yes to calculate the APW. The display shows the piece count.
  5. Add parts until you reach the count you need. Press Function to view the APW.

Percent mode

Press and hold Mode until Percnt shows. Press Yes to set a new reference, place the reference material and press Yes; the display shows 100%. Replace it with the sample and the display shows the sample as a percentage of the reference.

Check weighing

Press and hold Mode until Check shows, press Yes to set limits, and enter the low and high values digit by digit (No changes the digit, Yes accepts it). Then place the sample: the under, accept or over symbol lights. The balance supports positive, negative and zero check weighing.

Totalization and hold

In totalization, press Function after each item to store its weight and add it to the running total; only positive weights are totalized. Hold mode captures either the first stable weight (display hold, the default) or the highest stable weight (peak hold); both need a load of at least 5 divisions.

SPX1202 calibration

OHAUS says a span calibration is recommended when the balance is first used, and the balance must be calibrated again after it is moved. The security switch must be in the unlocked position, because a locked switch hides the calibration function and locks the units. The SPX1202 uses a 1 kg span mass and 500 g and 1 kg linearity masses, and OHAUS does not include a calibration weight with models above 620 g. We stock calibration weights, and our calibration weights guide explains classes.

Span calibration

  1. Press and hold Menu until MENU shows, then release. The display shows CAL.
  2. Press Yes to accept, and SPAN shows. Press Yes to begin.
  3. –C– shows while the zero reading is stored, with nothing on the pan.
  4. The display shows the calibration weight value (press No to toggle the value). Place the 1 kg mass on the pan.
  5. –C– shows while the reading is stored. When done shows, the balance returns to the previous mode.

For a linearity calibration, choose Lin instead of Span. It stores zero, a mid-point (500 g) and a span (1 kg) reading. If CAL E appears, the calibration failed, so check the security switch, the mass and a steady surface, and try again.

User menu, interfaces and extras

Press and hold Menu to enter the user menu with its Cal, Setup, Mode, Unit and End sub-menus. Setup holds the reset option, the filter (low, medium or high), auto zero tracking, the stable range, backlight, auto tare and auto off. The Mode menu switches counting, percent, check weighing, totalization and hold on or off, and the Unit menu turns each unit on or off.

The SPX1202 has a weigh-below hook behind the battery cover; before turning the balance over, remove the pan and set the transportation lock to locked. An optional interface kit adds RS232, USB host, USB device, Ethernet or Bluetooth for a computer or printer.

Error codes

DisplayMeaning and fix
Err 8.1 / Err 8.2The weight on the pan is above / below the power-on zero range. Clear the pan and restart.
Err 8.3Overload: the weight exceeds the rated capacity. Remove it.
Err 8.4Underload: the pan has been removed. Refit the pan.
Err 8.5The tare is out of range.
Err 8.6The displayed value exceeds 999999, which is possible in totalization.
ref.err / Lo.refThe counting or percent sample is too light for accurate results. Use a larger sample.
CAL EThe calibration failed. Check the security switch and mass, then repeat.

Clean the housing with a cloth dampened with mild detergent, and do not use solvents, alcohol, ammonia or abrasives. For service, contact us.

Calibration service from MNM Scales

Our TDA-registered technicians calibrate balances up to 2.2 kg like the SPX1202 in our shop, by mail-in from anywhere in the country, or at your site:

ServicePrice
In-house calibration with a certificate (NIST-tested weights)$95.00
NIST calibration with a NIST-traceable certificate$395.00
On-site service call$295 plus $2 per mile round trip, plus the per-scale rate

Add either calibration when you order the OHAUS SPX1202 and we calibrate it with its certificate. Our scale calibration cost guide lists every tier, and (832) 290-3120 books service.

NTEP and legal for trade

NCWM’s certificate search lists no NTEP Certificate of Conformance for the SPX1202, so the SPX1202 we sell at $741.99 is a Non-NTEP balance for classrooms, labs, field work and production checks. Here is an NTEP alternative: OHAUS SJX1502N/E, 1,500 g, NTEP Class II with e = 0.1 g (CC 16-015A2, Active), $275.00 (regular $1,507.00), in stock. Its NCWM Certificate of Conformance 16-015A2 (PDF) lists the SJX1502N/E by model, and we host it on our site. Read more in our NTEP balance guide.

Rules for commercial use

For commercial use in Texas, TDA inspectors use NIST Handbook 44 as the minimum standard. We recommend NTEP models, which meet those Handbook 44 requirements, and our TDA-registered technicians can check yours. See TDA’s scales used in trade guidance (PDF) and our TDA scale certification guide, or call us or TDA to confirm your use.

Frequently asked questions

Where can I find the SPX1202 manual?

The official manual is OHAUS’s Scout SPX series instruction manual, part number 30268991 rev F, which covers the SPX1202 and the rest of the SPX line. We host it as a PDF. This page walks through setup, modes, units and calibration.

How do I set up the OHAUS SPX1202?

Release the red transportation lock, fit the pan, level the balance with the feet until the bubble is centered, connect the AC adapter or four AA batteries and warm it up for at least 5 minutes. Calibrate it before use and after every move.

How do I calibrate the SPX1202?

Make sure the security switch is unlocked, hold Menu until MENU shows, press Yes at CAL and Yes at SPAN, wait for the zero reading, place the 1 kg mass when the display asks for it and wait for done.

What weight do I need for SPX1202 calibration?

The SPX1202 uses a 1 kg span mass, and a linearity calibration uses 500 g and 1 kg. We stock calibration weights.

How do I count parts on the SPX1202?

Tare a container, hold Mode until Count shows, choose 5, 10, 20, 50 or 100 samples, place that many pieces and press Yes to store the average piece weight. Then add the parts to count.

Is the SPX1202 NTEP?

The SPX1202 is a Non-NTEP balance for classrooms, labs and general weighing. Here is an NTEP alternative: OHAUS SJX1502N/E, 1,500 g, NTEP Class II with e = 0.1 g under CC 16-015A2 (Active), $275.00, in stock.

What does Err 8.3 mean on the SPX1202?

Err 8.3 is an overload: the weight on the pan exceeds the 1,200 g capacity. Remove the load. Err 8.4 means the pan has been removed, so refit it.

How much does SPX1202 calibration cost at MNM Scales?

For balances up to 2.2 kg, in-house calibration with a certificate is $95.00 and NIST calibration with a NIST-traceable certificate is $395.00. On-site calibration is $295 plus $2 per mile round trip, plus the per-scale rate. Mail-in works nationwide with the same in-house and NIST options.

About the author: MNM Scales

MNM Scales has sold, calibrated and repaired scales and balances for over 30 years. Our TDA-registered technicians calibrate in-house with certificates, offer mail-in and on-site calibration, place commercial scales in service in Texas, and rent all types of scales. We supply customers across aerospace, oil and gas, food, plastics, chemicals, pharmacies to big pharma and pawn shops. Shop: 21249 FM 529 Rd, Cypress, TX 77433 (by appointment). Call (832) 290-3120 or contact us.

Last updated November 26, 2026. Sources: OHAUS Scout SPX instruction manual 30268991 rev F (PDF) and NCWM Certificate of Conformance 16-015A2, both hosted on mnmscales.com; live store listings #901, #500, #42460 and #42461; and Texas Department of Agriculture legal-for-trade guidance. Prices from our live store on November 26, 2026.