We are a US-based dealer shipping directly from Houston, TX!
Contact us for expedited, Alaska, Hawaii, and International shipping rates

We will BEAT competitors' pricing when you contact directly!

mnmscales@yahoo.com
(832) 290-3120

Contact Us for More Details on price beating competitors' when you text/email/phone call, and for payments, specific/niche models, bulk orders, use cases/hobbies, plus any other questions!
Direct Bank Transfers are accepted.

MNM Scales LLC
(832) 290-3120
mary@mnmscales.com
sales@mnmscales.com
21249 FM 529 Rd,
Cypress, TX 77433

We accept PayPal Buy Now, Pay Later feature. All credit/debit cards are accepted.

FS-15Ki Manual: Setup, Keys, Check Weighing, Units and Calibration

This FS-15Ki manual page covers setup, the keys, check weighing, units and calibration for the A&D FS-15Ki, which is in stock at $929.00.

Short answer: the official FS-15Ki manual is A&D’s A&D FS-i series instruction manual (PDF) for the FS-i series, and we host it, along with the FS-i datasheet (PDF). To set the scale up, attach the display pod to the support column, level the base with the spirit level and leveling feet, plug the power cord into an earthed outlet and press ON/OFF. For check weighing, press SAMPLE to register a sample as the target (or KEY to type it), press HI and LO to enter the limits, and watch the red, green and yellow lights. To calibrate, hold the CAL switch under the rear cover until Cal shows and follow the prompts with a 15 kg weight.

On sale: $929.00 (regular $1,550.00) on the A&D FS-15Ki, in stock. Contact us or call (832) 290-3120 with a question about setup or calibration.

Shop the FS-15Ki   Call (832) 290-3120   Get a Quote

This FS-15Ki manual page walks through A&D’s A&D FS-i series instruction manual (PDF) for the A&D FS-15Ki, the 15 kg (35 lb) washdown checkweighing scale with red, green and yellow comparator lights, a 60-segment analog sweep display, IP65 protection, NSF listing and a stainless steel (SUS304) pan, column and display pod. It shows how to set up the scale, what each key does, how to set a target weight and HI and LO limits, how to switch units and display steps, how to calibrate it, and how to read the messages. A&D’s FS-i datasheet (PDF) and FS-i addendum (PDF) are hosted here too. For how checkweighing works across the family, read our checkweigher scales guide and our washdown checkweigher guide.

FS-15Ki at a glance

Prices are from our live store on November 26, 2026. Display steps are the finest setting for each model (see the resolution section below).

ModelCapacity × display stepPanPrice
A&D FS-6Ki15 lb × 0.001 lb (6 kg)250 × 250 mm$929.00 (reg. $1,550.00), in stock
A&D FS-15Ki35 lb × 0.002 lb (15 kg)250 × 250 mm$929.00 (reg. $1,550.00), in stock
A&D FS-30Ki70 lb × 0.005 lb (30 kg)380 × 300 mm$1,079.23 (reg. $1,805.00), in stock
A&D HV-15KC (NTEP)6/15/30 lb × 0.002/0.005/0.01 lb (triple range)250 × 250 mm$638.00 (reg. $1,190.00), in stock
ItemFS-15Ki specification
Capacity15 kg / 35 lb / 15,000 g / 560 oz
Display steps, NORMAL (factory)0.005 kg, 5 g, 0.01 lb, 0.2 oz
Display steps, HIGH0.002 kg, 2 g, 0.005 lb, 0.1 oz
Display steps, HIGHER0.001 kg, 1 g, 0.002 lb, 0.05 oz
Weighing unitskg, g, lb, oz and lb-oz
Repeatability (standard deviation)0.002 kg
Linearity error±0.005 kg
Span drift±20 ppm per °C (5 to 35 °C / 41 to 95 °F)
ComparatorLO (red), OK (green) and HI (yellow) lights with a buzzer; 100 stored sets of limits (00 to 99)
Display7-segment LCD with backlight (18.6 mm characters) and a 60-segment analog sweep display with backlight
Display update / stabilizationAbout 20 times per second; stabilization in about 0.5 seconds (A&D datasheet)
ProtectionIP65 (dust-tight, protected against water jets); NSF/ANSI 169 listed
ConstructionStainless steel (SUS304) pan, column and display pod
Pan size250 × 250 mm (9.8 × 9.8 in)
Dimensions250 (W) × 414 (D) × 496 (H) mm / 9.8 × 16.3 × 19.5 in
Weight (approx.)8.1 kg / 17.9 lb
Operating conditions-10 to 40 °C (14 to 104 °F), less than 85% RH, indoor use only, altitude up to 2,000 m
PowerAC mains 100 to 240 V, or an optional sealed lead acid battery
Sensitivity adjustment weight15 kg / 30 lb
NTEPNon-NTEP. Here is an NTEP alternative: the A&D HV-15KC (6/15/30 lb triple range, comparator lights, NTEP Class III, $638.00, in stock)

Sources: the A&D FS-i series instruction manual (PDF) (section 15, specifications) and the FS-i datasheet (PDF). Calibration weights are not included with the scale.

Setting up the FS-15Ki

A&D’s manual sets up the scale in two steps. If the display pod is not attached to the display support column:

  1. Take the scale out of the box without pulling the load cell cable, then remove the 2 clamps and 2 M4×12 screws.
  2. Attach the display pod to the display support column and tighten the M4×12 screws.
  3. Fit the clamps after tilting the pod to the angle you like, and tuck the extra load cell cable into the column.

Then install the scale:

  1. Pick the spot. A&D asks for a solid, level surface with stable temperature and humidity, no draft, a stable power source and no direct sunlight, heaters, air conditioners, corrosive gas or strong magnetic fields. The AC plug is not water-resistant, so keep it where it stays dry.
  2. Level the base with the spirit level and the leveling feet. An extra foot sits under the display support column; adjust it to reach the floor after the base is level.
  3. Connect power. Plug the power cord into an outlet that has earth wiring.
  4. Adjust the viewing angle by loosening the 2 clamps, changing the angle and tightening them again.

Press ON/OFF to turn the scale on. All symbols light and the scale waits for a stable reading, then shows zero with the ZERO annunciator. If the display keeps showing 88888888, check that nothing touches the pan and that there is no strong wind or vibration. A&D recommends pressing ZERO or TARE before each weighing, and always reading or storing a value only when the STABLE annunciator is on. Calibrate the scale when you first use it, when you move it, and on a regular schedule.

Keys on the FS-15Ki

KeyWhat it does
ON/OFFTurns the scale on or off; on start-up the scale sets itself to zero
ZERO / ±Zeros the scale when the reading is stable; in data entry it switches the sign between plus and minus
TARESwitches to net weight and zeros the display (ZERO and NET annunciators light)
PTEnters a known tare weight with the keypad
SAMPLE / 9Registers the sample on the pan as the target weight
KEY / 8Lets you type the target weight
RECALL / 7Recalls a stored target and HI/LO limits
HI / 6 and LO / 5Enter the HI and LO limits
STORE / 4Stores the target and limits in memory
DISP. / 3Steps the analog display through simple weighing, target weighing, limit check weighing and off
UNITS / 1Selects the weighing unit
PRINT / ENTSends data when an optional serial interface is installed; in data entry it enters the number
CClears a wrong entry
0 and 2Number keys for data entry

Stable, zero, net, preset tare (PT), print and low battery have their own annunciators, and the LO (red), OK (green) and HI (yellow) lights show the comparison result.

Weighing, tare and units

Basic weighing

  1. Press ON/OFF and press UNITS to cycle to the unit you need (kg, g, lb, oz or lb-oz).
  2. Press ZERO if the display is not at zero.
  3. For a container, place it on the pan and press TARE; the display returns to zero as net weight.
  4. Place the product, wait for the STABLE annunciator and read the value, then remove the product.

Preset tare and clearing tare

To use a known tare weight, empty the pan, press PT, type the tare with the keypad and press ENT. The NET annunciator lights. The preset tare is lost when the power goes off. To clear a tare, empty the pan and press ZERO, or press PT, then 0, then ENT.

Units and display steps

Function F3 chooses the unit the scale shows at power-on (0 kg, 1 g, 2 lb, 3 oz, 4 lb-oz). Function F2 chooses the display resolution: 0 is NORMAL (1/3,000), 1 is HIGH (1/6,000 to 1/7,500) and 2 is HIGHER (1/12,000 to 1/15,000). The factory setting is NORMAL, which on the FS-15Ki is 0.005 kg or 0.01 lb. The 0.002 lb step in the product title is the HIGHER setting, so set F2 to 2 to get it. Function F13 sets zero tracking and F14 can limit the keys for operators (see the function table).

Check weighing on the FS-15Ki

The comparator compares each weight with limits and lights LO (below), OK (within) or HI (above), with an optional buzzer. Before you use it, set the comparison mode with F7, the compare condition with F8, and the buzzer with F9. A&D’s manual describes two modes.

Target weight mode (F7-1 or F7-2)

You set a target weight and a HI and LO tolerance. With F7-1 the tolerances are weights; with F7-2 they are a percentage of the target. The OK range runs from the target minus the LO limit to the target plus the HI limit.

  • Target by sample: zero the scale, place the sample, press SAMPLE, wait for STABLE and press ENT. The display shows Stored.
  • Target by key: press KEY, type the target with the keypad and press ENT.
  • Limits: press HI, type the HI limit, press ENT; press LO, type the LO limit, press ENT. The LO limit does not take a sign.

Example from the manual: a 3.000 kg target with HI 0.050 kg and LO 0.030 kg gives OK from 2.970 kg to 3.050 kg.

Upper and lower limit mode (F7-0)

Set F7-0, then press HI and type the upper limit weight and press ENT, and press LO and type the lower limit weight and press ENT. No target is used. A weight from the lower limit to the upper limit lights OK.

Memory, analog display and auto-tare

  • Store a set: enter the target and limits, press STORE, type a memory number from 00 to 99 and press ENT. Recall a set with RECALL, the number and ENT. Memory is not available in simplified operation mode.
  • Analog sweep display: press DISP. to step through simple weighing (zero to full scale), target weighing (the target is the flashing 40th segment) and limit check weighing (the lower limit is the flashing 21st segment and the upper limit the 40th) or turn it off. F16 sets the mode at power-on.
  • Auto-tare and take-away: with F8-1 and F21-1 the scale tares automatically when the weight is OK and stable; F22 sets the delay from immediately to 6 seconds. F24-1 turns on negative comparison for take-away check weighing, and F23-1 tares the starting container weight. See A&D’s FS-i addendum (PDF) for these functions.
  • Simplified operation: F14-1 leaves ON/OFF, ZERO, TARE, SAMPLE and PRINT/ENT active, and F14-2 leaves ON/OFF, ZERO and TARE only, so settings cannot change by accident. Set F3 and F16 first, because units and the analog display cannot be changed in these modes.

Function settings

To open the function list, turn the scale off, hold ZERO and press ON/OFF. Key in the function number and press ENT to see its value, key in the new value, press ZERO to move to the next function if you need to, and press ENT. The new values are stored when end shows. A&D lists these among its 24 functions:

FunctionSetting
F10 auto power-off off, 1 on (about 5 minutes at zero)
F2Display resolution: 0 NORMAL, 1 HIGH, 2 HIGHER
F3Unit at power-on: kg, g, lb, oz, lb-oz
F7Comparison mode: 0 upper and lower limits, 1 target with weight limits, 2 target with percent limits
F8When to compare: 0 off, 1 all data, 2 stable data, 3 to 6 add a 4-division threshold
F9Buzzer on LO, OK, HI or any combination
F10 to F12Response and filtering, stability width and stability time
F13Zero tracking off or on at three speeds
F14Key operation: 0 all keys, 1 or 2 simplified
F15 to F17Comparator light brightness, analog display at power-on, LCD backlight (always off, always on, or off after 30 or 60 seconds of stability)
F21 to F24Auto-tare, auto-tare timing, tare the initial container weight, negative comparison

F4 to F6 and F18 to F20 set up the optional serial interfaces.

Messages on the display

DisplayMeaningWhat to do
88888888 at start-upThe reading is not stable yet.Check that nothing touches the pan and that there is no wind or vibration.
Dashes at start-upA load beyond ±50% of capacity is on the pan at power-on.Remove the load and turn the scale on again.
StoredA target, limit or memory set was saved.Nothing; the scale returns to weighing.
endFunction settings or calibration were saved.Turn the power off after calibration.
Over range marksThe weight is outside the range of the analog sweep display.Check the target and limits you entered.
Low battery annunciatorThe optional battery is close to empty.Connect the power cord to charge it.

Do not place more than 15 kg (35 lb) on the pan, do not drop loads on it, and do not press the keys with a pencil or pen. If a message stays, call us; we repair all brands and types of scales at our Cypress, TX shop (by appointment) or by mail-in. Our scale error codes guide covers common display messages.

Cleaning

A&D says to wipe the display pod with a lint-free cloth, dry or moistened with warm water and mild detergent. The base can be cleaned with a gentle water jet and brushing; dry it well before use. Do not use a powerful water jet or solvents, and do not disassemble the scale. Our washdown scales guide explains what IP65 covers.

Battery and options

The FS-15Ki runs from AC power (100 to 240 V) or from an optional sealed lead acid battery. A&D’s manual lists a fully charged battery as lasting about 80 hours with the backlight and comparator light off, about 55 hours with the comparator light on, and about 25 hours with the backlight and comparator light both on. A full charge takes about 15 hours, and the scale can be used while it charges. Charge the battery before first use, and recharge a stored battery every 3 months in a warm area or every 6 months in a cool one. The battery is a GS Yuasa NP4-6 (6 V, 4 Ah); connect red to positive and black to negative. Our scale battery replacement guide explains matching voltage and a safe swap.

ItemUse on the FS-15KiPrice
A&D HC-02i-FS Rechargeable BatteryBattery for FS-i checkweighing scales, installation included$79.00 (reg. $99.00), in stock
A&D FS-04i RS-422/485 InterfaceOptional RS-422/485 and relay output interface for FS-i scales$51.90 (reg. $185.03), in stock

A&D also offers an RS-232C and relay output interface (FS-03i) for connecting a printer or computer; the PRINT key sends data when an interface is installed. Call us to ask about interface options.

FS-15Ki calibration

The manual calls calibration “sensitivity adjustment.” A&D says to calibrate when the scale is first used, after it moves, when the environment changes, and on a regular schedule. The steps are:

  1. Warm up the scale for at least half an hour with the pan empty, and turn off auto-power-off (F1) or leave something on the pan so it stays on.
  2. Open the CAL switch. Loosen the lock screws on the rear of the display pod and remove the CAL switch cover. Hold the CAL switch until Cal shows (holding the 0 key for about 5 seconds also works). If F14 is set to anything other than 0, calibration cannot be entered.
  3. Press ENT to see the gravity acceleration value and press ENT again to reach Cal 0.
  4. Zero point: empty the pan, wait for STABLE and press ENT. The display shows the span prompt with the weight value, which starts at the capacity; the keypad changes it to the weight you will use.
  5. Span: place a weight equal to the displayed value (A&D lists 15 kg or 30 lb), wait for STABLE and press ENT. When end shows, remove the weight and turn the power off.

If you have no weight, the manual allows a gravity acceleration correction: at the gravity prompt you key in the value for your area, taken from the gravity map in section 16. Calibration weights are not included with the scale; we stock calibration weights and explain them in our calibration weights guide. Our how to calibrate a scale guide covers the general method. Or let us do it. The FS-15Ki is 15 kg, so it falls in the 6.2 to 35 kg tier:

OptionWhat you getPrice
In-house calibrationCalibrated with NIST-tested weights, certificate included$250.00
NIST calibrationCalibrated with a NIST-traceable certificate$595.00
On-site calibrationOur technicians come to your location$295 plus $2 per mile, round trip, once per visit, plus the per-scale rate above
Mail-in calibrationNationwide by mail, with in-house calibration or NIST calibrationSame $250.00 or $595.00 rates

Calibration usually takes 1 to 3 business days after we receive the scale. Ask for our scale calibration service in Houston, or add calibration to the A&D FS-15Ki when you order and we calibrate it before it ships. Our scale calibration cost guide and NIST vs in-house certificate guide help you choose, and our scale tolerance calculator shows acceptable error for a given division. For repairs, get a quote or call (832) 290-3120.

NTEP and legal for trade

The FS-15Ki on this page is a Non-NTEP checkweigher. Here is an NTEP alternative: the A&D HV-15KC (6/15/30 lb triple range x 0.002/0.005/0.01 lb, comparator lights, NTEP Class III under CC 17-099A3, $638.00, in stock). It suits portioning, packing, fill checks and quality control where the weight is not the basis of a sale. A&D’s NTEP certificate for the FSi series is NCWM Certificate of Conformance 07-104A2 (PDF) (Active, issued September 2, 2025). It lists the legal-for-trade FS-15KiF and FS-15KiNF at 35 lb × 0.01 lb (15 kg × 0.005 kg), Class III, nmax 3,500, with the same 250 × 250 mm pan, and the certificate says the calibration switch is sealed with a wire security seal. Those are separate models from the FS-15Ki above, and the manual says legal-for-trade FS-i models are fixed at NORMAL resolution. Our what is NTEP guide explains the classes and certificates, and our free legal-for-trade scale checker helps you decide whether your use counts as trade. Call us if you need a legal-for-trade checkweigher.

Rules for commercial use

For commercial use in Texas, TDA inspectors use NIST Handbook 44 as the minimum standard. We recommend NTEP models, which meet those Handbook 44 requirements, and our TDA-registered technicians can check yours. See TDA’s scales used in trade guidance (PDF) and our TDA scale certification guide, or call us or TDA to confirm your use.

Frequently asked questions

Where can I find the FS-15Ki manual?

The official manual is A&D’s instruction manual for the FS-i series, which covers the FS-6Ki, FS-15Ki and FS-30Ki. We host it as a PDF. A&D’s datasheet and addendum are hosted on this page as well. This page walks through setup, keys, check weighing, units and calibration.

How do I set up the A&D FS-15Ki?

Attach the display pod to the support column if it is not attached, level the base with the spirit level and leveling feet, adjust the extra foot under the column, plug the power cord into an earthed outlet and press ON/OFF. When the display shows zero with the ZERO annunciator, the scale is ready.

How do I set the target and HI and LO limits on the FS-15Ki?

Set F7-1 for target weight mode. Place a sample, press SAMPLE and ENT to store it as the target, or press KEY and type it. Press HI and type the HI limit, then press LO and type the LO limit, pressing ENT each time. The red LO, green OK and yellow HI lights then show each weight.

Why does my FS-15Ki show 0.01 lb instead of 0.002 lb?

The factory display setting is NORMAL, which is 0.005 kg or 0.01 lb on the FS-15Ki. To get 0.002 lb, open the function list (hold ZERO and press ON/OFF), set F2 to 2 for the HIGHER resolution and press ENT.

How do I calibrate the FS-15Ki?

Warm up the scale for half an hour, remove the CAL switch cover on the rear of the display pod and hold the switch until Cal shows. Press ENT twice, zero the empty pan with ENT, then place the 15 kg weight A&D lists and press ENT until end shows. We stock calibration weights if you need one.

How much does FS-15Ki calibration cost at MNM Scales?

A 15 kg scale is in the 6.2 to 35 kg tier: in-house calibration with a certificate is $250.00 and NIST calibration with a NIST-traceable certificate is $595.00. On-site calibration is $295 plus $2 per mile, round trip, plus the per-scale rate. Mail-in works nationwide with the same in-house and NIST options.

Is the FS-15Ki NTEP legal for trade?

No. The FS-15Ki is a Non-NTEP checkweigher for portioning, packing and quality control. Here is an NTEP alternative: the A&D HV-15KC (6/15/30 lb triple range x 0.002/0.005/0.01 lb, comparator lights, NTEP Class III under CC 17-099A3, $638.00, in stock). A&D’s NTEP certificate 07-104A2 lists the legal-for-trade FS-15KiF and FS-15KiNF, which are separate models. Call us if you need a legal-for-trade checkweigher.

How long does the FS-15Ki battery last, and can I wash the scale down?

With the optional battery, A&D lists about 80 hours with the backlight and comparator light off and about 25 hours with both on, and a charge takes about 15 hours. We stock the A&D HC-02i-FS Rechargeable Battery for FS-i scales. The scale is IP65 with a stainless steel pan: wipe the display pod with a damp lint-free cloth and clean the base with a gentle water jet and brushing, never a powerful jet or solvents.

About the author: MNM Scales

MNM Scales has sold, calibrated and repaired scales and balances for over 30 years. Our TDA-registered technicians calibrate in-house with certificates, offer mail-in and on-site calibration, place commercial scales in service in Texas, and rent all types of scales. We supply customers across aerospace, oil and gas, food, plastics, chemicals, pharmacies to big pharma and pawn shops. Shop: 21249 FM 529 Rd, Cypress, TX 77433 (by appointment). Call (832) 290-3120 or contact us.

Last updated November 26, 2026. Sources: A&D FS-i series instruction manual (PDF), FS-i datasheet (PDF), FS-i addendum (PDF) and NCWM Certificates of Conformance 07-104A2 and 17-099A3, all hosted on mnmscales.com; live store listings #1450, #1939, #2028, #6088, #41878, #42125, #42473 and #42474; and Texas Department of Agriculture legal-for-trade guidance. Prices from our live store on November 26, 2026.

Leave a Comment